Delta Charger Error Codes

004001

System input voltage is higher than workable range(>305 volt)

004002

System input voltage (L1, L2 or L3) is lower than workable range (<170 volt)

004005

Temperature of air inlet or input contactor is higher than workable range

004006

Temperature of CCS combo charging plug is higher than workable range

004007

Air filters need to be replaced

004008

System fan error

004009

System Init Failed

00400A

Emergency button is pressed

00400D

Temperature sensor of air inlet is broken

00400E

Temperature sensor of input contactor is broken

00400F

SPD trigger

004010

Output fuse on CCS relay board is broken

004011

Output fuse on CHAdeMO relay board is broken

004012

Temperature sensor of CCS combo charging plug is broken

004013

Temperature of air inlet is lower than workable range

004014

Stop charging by RFID

004015

The plug-in times of CCS charging plug is more than 10000 times

004016

The plug-in times of CHAdeMO charging plug is more than 10000 times

004017

System is timeout if user doesn't plug-in in 5 minutes after authorized => Action item shall add check gun

004018

Charging time is up

004022

Input voltage is drop (L1) (<20V, 100ms)

004024

System reach stop SoC

004025

System reach stop energy

005006

Communication with SMR is broken

005007

Communication with CCS controller is broken

005008

Communication with auxiliary power module is broken

005009

Communication with relay control module is broken

00500D

Communication with RFID module is broken

00500E

3G module is not ready

006002

3G connection is disconnected from internet

006003

3G connection is disconnected from backend office

006009

Ethernet connection is disconnected from backend office

007001

Power rectifier is abnormal

007002

Input voltage of power rectifier is higher than workable range

007003

Input voltage of power rectifier is lower than workable range

007004

Output voltage is higher than workable range of power rectifier

007006

The temperature of air inlet in power rectifier is higher than workable range

00700C

The fan inside power rectifier is broken

008003

5 volt for system controller is higher than workable range

008004

5 volt for other system modules is higher than workable range

008005

5 volt for CAN bus is higher than workable range

008006

12 volt for other system modules is higher than workable range

008007

12 volt for EV communication is higher than workable range

008008

24 volt for relay control is higher than workable range

008009

5 volt for system controller is lower than workable range

00800A

5 volt for other system modules is lower than workable range

00800B

5 volt for CAN bus is lower than workable range

00800C

12 volt for other system modules is lower than workable range

00800D

12 volt for EV communication is lower than workable range

00800E

24 volt for relay control is lower than workable range

008019

The ambinet temperature of auxiliary power is higher than workable range

009001

GFD trigger

009003

GFD pre-warnning

00A001

Input contactor 1 is welding

00A003

Input contactor 2 is welding

00A00E

The output relay for CCS charging is drived fault

00A00F

The output relay for CHAdeMO charging is welding

00A010

The output relay for CHAdeMO charging is drived fault

00A012

The output pre-charge relay for CCS charging is drived fault

00A013

CCS pilot line is broken

00A014

CCS proximity is broken

00B001

The firmware update of auxiliary power module is failure

00B002

The firmware update of relay control module is failure

00B003

The firmware update of LCM module is failure

00B004

The firmware update of CCS charging module is failure

00B005

The firmware update of CHAdeMO charging module is failure

00B006

The firmware update of power converter module is failure

00C002

CCS1 proximity is disconnected

00C100

SLAC - No data

00C101

SLAC error

00C102

SDP error

00C103

TCP error

00C104

V2G error - Idle

00C105

V2G error - supportedAppProtocol

00C106

V2G error - SessionSetup

00C107

V2G error - ServiceDiscovery

00C108

V2G error - ServicePaymentSelection

00C109

V2G error - ContractAuthentication

00C10A

V2G error - ChargeParameterDiscovery

00C10B

V2G error - CableCheck

00C10C

V2G error – PreCharge

00C10D

V2G error – PowerDelivery

00C10E

V2G error – CurrentDemand

00C202

Timeout error – ReadyToCharge

00C203

CableCheck error - SMR Vout is less than Vcmd

00C204

CableCheck error - SMR Vout is over 20V

00C205

CableCheck error - Output voltage is over 60V before insulation test

00C206

CableCheck error - Output current is over 2A in insulation test

00C207

Precharge error - Output voltage is less than EV Vcmd

00C208

Precharge error - Output current is over 1.5A in precharge

00C300

EV error - FAILED_RESSTemperatureInhibit

00C301

EV error - FAILED_EVShiftPosition

00C302

EV error - FAILED_ChargerConnectorLockFault

00C303

EV error - FAILED_EVRESSMalfunction

00C304

EV error - FAILED_ChargingCurrentdifferential

00C305

EV error - FAILED_ChargingVoltageOutOfRange

00C306

EV error - FAILED_Reserved_A

00C307

EV error - FAILED_Reserved_B

00C308

EV error - FAILED_Reserved_C

00C309

EV error - FAILED_ChargingSystemIncompatibility

00C30A

EV error - FAILED_NoData

00C30B

Stop charging at supportedAppProtocol

00C30C

Stop charging at SessionSetup

00C30D

Stop charging at ServiceDiscovery

00C30E

Stop charging at ServicePaymentSelection

00C30F

Stop charging at ContractAuthentication

00C310

Stop charging at ChargeParameterDiscovery

00C311

Stop charging at CableCheck

00C312

Stop charging at PreCharge

00C313

Stop charging at CurrentDemand

00C314

Stop charging at CurrentDemand by PowerDelivery(BulkChargingComplete)

00C315

Stop charging at CurrentDemand by PowerDelivery(ChargingComplete)

00C316

Stop charging by pilot A

00C317

Stop charging by pilot B

00C318

Stop charging by pilot E, F or error

00D001

No charging permission come from CHAdeMO EV

00D003

Target battery voltage is higher than available output voltage

00D004

Battery undervoltage

00D005

Battery overvoltage

00D006

Present output current is different from target current

00D007

Battery OTP come from CHAdeMO EV

00D008

Present output voltage is different from target voltage

00D009

Position shift alarm is come from CHAdeMO EV

00D00A

EV other fault is come from CHAdeMO EV

00D00B

CHAdeMO connector lock is broken

00D00D

Battery malfunction - Target battery voltage is higher than maximum battery voltage

00D00E

Charging current request is higher than available output current

00D00F

Timeout error - Start of Vehicle CAN data

00D010

Timeout error - CAN communication fault

00D011

Timeout error - Charging enable

00D012

Timeout error - EV contactor close

00D013

Timeout error - Charging current request

00D014

Insulation error - SMR Vout is less than Vcmd

00D015

Insulation error - SMR Vout is over 20V

00D016

Insulation error - Output voltage over 10V before insulation test

00D017

Insulation error - Output voltage over 20V after insulation test

00D018

Insulation error - Output current is over 2A in insulation test

00D019

Vehicle voltage error - Output voltage over 10V after charging

00D01B

CHAdeMO system error - process

00D01C

CHAdeMO EV permission disable time out after charging

00D01D

CHAdeMO EV contactor open time out after charging

00D01E

System output voltage is higher than EV battery maximum voltage

00D01F

Permission on or H102.5.0 = 1 before CAN message received.