Delta Charger Error Codes
004001
System input voltage is higher than workable range(>305 volt)
004002
System input voltage (L1, L2 or L3) is lower than workable range (<170 volt)
004005
Temperature of air inlet or input contactor is higher than workable range
004006
Temperature of CCS combo charging plug is higher than workable range
004007
Air filters need to be replaced
004008
System fan error
004009
System Init Failed
00400A
Emergency button is pressed
00400D
Temperature sensor of air inlet is broken
00400E
Temperature sensor of input contactor is broken
00400F
SPD trigger
004010
Output fuse on CCS relay board is broken
004011
Output fuse on CHAdeMO relay board is broken
004012
Temperature sensor of CCS combo charging plug is broken
004013
Temperature of air inlet is lower than workable range
004014
Stop charging by RFID
004015
The plug-in times of CCS charging plug is more than 10000 times
004016
The plug-in times of CHAdeMO charging plug is more than 10000 times
004017
System is timeout if user doesn't plug-in in 5 minutes after authorized => Action item shall add check gun
004018
Charging time is up
004022
Input voltage is drop (L1) (<20V, 100ms)
004024
System reach stop SoC
004025
System reach stop energy
005006
Communication with SMR is broken
005007
Communication with CCS controller is broken
005008
Communication with auxiliary power module is broken
005009
Communication with relay control module is broken
00500D
Communication with RFID module is broken
00500E
3G module is not ready
006002
3G connection is disconnected from internet
006003
3G connection is disconnected from backend office
006009
Ethernet connection is disconnected from backend office
007001
Power rectifier is abnormal
007002
Input voltage of power rectifier is higher than workable range
007003
Input voltage of power rectifier is lower than workable range
007004
Output voltage is higher than workable range of power rectifier
007006
The temperature of air inlet in power rectifier is higher than workable range
00700C
The fan inside power rectifier is broken
008003
5 volt for system controller is higher than workable range
008004
5 volt for other system modules is higher than workable range
008005
5 volt for CAN bus is higher than workable range
008006
12 volt for other system modules is higher than workable range
008007
12 volt for EV communication is higher than workable range
008008
24 volt for relay control is higher than workable range
008009
5 volt for system controller is lower than workable range
00800A
5 volt for other system modules is lower than workable range
00800B
5 volt for CAN bus is lower than workable range
00800C
12 volt for other system modules is lower than workable range
00800D
12 volt for EV communication is lower than workable range
00800E
24 volt for relay control is lower than workable range
008019
The ambinet temperature of auxiliary power is higher than workable range
009001
GFD trigger
009003
GFD pre-warnning
00A001
Input contactor 1 is welding
00A003
Input contactor 2 is welding
00A00E
The output relay for CCS charging is drived fault
00A00F
The output relay for CHAdeMO charging is welding
00A010
The output relay for CHAdeMO charging is drived fault
00A012
The output pre-charge relay for CCS charging is drived fault
00A013
CCS pilot line is broken
00A014
CCS proximity is broken
00B001
The firmware update of auxiliary power module is failure
00B002
The firmware update of relay control module is failure
00B003
The firmware update of LCM module is failure
00B004
The firmware update of CCS charging module is failure
00B005
The firmware update of CHAdeMO charging module is failure
00B006
The firmware update of power converter module is failure
00C002
CCS1 proximity is disconnected
00C100
SLAC - No data
00C101
SLAC error
00C102
SDP error
00C103
TCP error
00C104
V2G error - Idle
00C105
V2G error - supportedAppProtocol
00C106
V2G error - SessionSetup
00C107
V2G error - ServiceDiscovery
00C108
V2G error - ServicePaymentSelection
00C109
V2G error - ContractAuthentication
00C10A
V2G error - ChargeParameterDiscovery
00C10B
V2G error - CableCheck
00C10C
V2G error – PreCharge
00C10D
V2G error – PowerDelivery
00C10E
V2G error – CurrentDemand
00C202
Timeout error – ReadyToCharge
00C203
CableCheck error - SMR Vout is less than Vcmd
00C204
CableCheck error - SMR Vout is over 20V
00C205
CableCheck error - Output voltage is over 60V before insulation test
00C206
CableCheck error - Output current is over 2A in insulation test
00C207
Precharge error - Output voltage is less than EV Vcmd
00C208
Precharge error - Output current is over 1.5A in precharge
00C300
EV error - FAILED_RESSTemperatureInhibit
00C301
EV error - FAILED_EVShiftPosition
00C302
EV error - FAILED_ChargerConnectorLockFault
00C303
EV error - FAILED_EVRESSMalfunction
00C304
EV error - FAILED_ChargingCurrentdifferential
00C305
EV error - FAILED_ChargingVoltageOutOfRange
00C306
EV error - FAILED_Reserved_A
00C307
EV error - FAILED_Reserved_B
00C308
EV error - FAILED_Reserved_C
00C309
EV error - FAILED_ChargingSystemIncompatibility
00C30A
EV error - FAILED_NoData
00C30B
Stop charging at supportedAppProtocol
00C30C
Stop charging at SessionSetup
00C30D
Stop charging at ServiceDiscovery
00C30E
Stop charging at ServicePaymentSelection
00C30F
Stop charging at ContractAuthentication
00C310
Stop charging at ChargeParameterDiscovery
00C311
Stop charging at CableCheck
00C312
Stop charging at PreCharge
00C313
Stop charging at CurrentDemand
00C314
Stop charging at CurrentDemand by PowerDelivery(BulkChargingComplete)
00C315
Stop charging at CurrentDemand by PowerDelivery(ChargingComplete)
00C316
Stop charging by pilot A
00C317
Stop charging by pilot B
00C318
Stop charging by pilot E, F or error
00D001
No charging permission come from CHAdeMO EV
00D003
Target battery voltage is higher than available output voltage
00D004
Battery undervoltage
00D005
Battery overvoltage
00D006
Present output current is different from target current
00D007
Battery OTP come from CHAdeMO EV
00D008
Present output voltage is different from target voltage
00D009
Position shift alarm is come from CHAdeMO EV
00D00A
EV other fault is come from CHAdeMO EV
00D00B
CHAdeMO connector lock is broken
00D00D
Battery malfunction - Target battery voltage is higher than maximum battery voltage
00D00E
Charging current request is higher than available output current
00D00F
Timeout error - Start of Vehicle CAN data
00D010
Timeout error - CAN communication fault
00D011
Timeout error - Charging enable
00D012
Timeout error - EV contactor close
00D013
Timeout error - Charging current request
00D014
Insulation error - SMR Vout is less than Vcmd
00D015
Insulation error - SMR Vout is over 20V
00D016
Insulation error - Output voltage over 10V before insulation test
00D017
Insulation error - Output voltage over 20V after insulation test
00D018
Insulation error - Output current is over 2A in insulation test
00D019
Vehicle voltage error - Output voltage over 10V after charging
00D01B
CHAdeMO system error - process
00D01C
CHAdeMO EV permission disable time out after charging
00D01D
CHAdeMO EV contactor open time out after charging
00D01E
System output voltage is higher than EV battery maximum voltage
00D01F
Permission on or H102.5.0 = 1 before CAN message received.